Replacement Filter for Magenta Voyager 160-port switch.
The pictures show both sides of the filter. The filter is installed with the aluminum mesh facing outward and the "foam side" faces inward towards the fan tray.
The Voyager Matrix Fiber Switch features filtered air cooling.
A removable filter is located behind an access panel on the right side when facing the front of the frame.
This filter is easily removed by sliding out towards the front.
It is important that the air filter be serviced periodically to ensure proper cooling of internal components.
A recommended starting point is to assume a service interval of 30 days. However, the required service interval may vary, depending on the level of ambient dust and other contaminants.
Although the air filter should be replaced at each service interval, it is sometimes possible to extend the replacement intervals by simply cleaning it with a suitable vacuum. Eventually you will need to actually replace the air filter. So as to not damage the filter, do not vacuum the foam side of the filter. It is not recommended to immerse the filter in water.
Remember to reset fan Filter Service Interval after each cleaning/replacement
Replacement filters and access covers may be obtained by calling svideo.com at 956-566-4520 or just order it online here.
Replacement part numbers are:
- 48-port switch filter, part number 2390102-01
- 48-port access cover, part number 2390106-01
- 160-port switch filter, part number 2390101-01 (order it online above)
- 160-port access cover, part numbner 2390105-01
To open the access cover & remove filter:
- Press in and push up on the unlock image located at the top of the access panel. The access cover should unlock and can be easily removed. This will expose the filter element.
- Grasping the white plastic loop in the middle of the filter_s front section, carefully pull out the filter.
- Vacuum or replace as required.
To replace filter & close access cover:
- With the air-filter properly oriented (foam gasket facing towards the fan-tray) carefully slide the filter all the way into the switch.
- With clips facing upward, slip the cover panel up into the access-cover opening. Note the orientation of the _LOCK_ symbols and arrows. The arrows should point to each other.
- Press on the lower end of the access cover and carefully slide it downwards. You may hear or feel a
_click_ at the top of the access-cover. This indicates the cover has been properly installed and locked
into place.